action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /var/www/wp-includes/functions.php on line 6114The following glossary is based on information provided by topten.eu and taken from additional sources such as technical standards and legislative documents.
COP – Coefficient of Performance: the ratio of heat output delivered to the heating circuit against the electrical input. An example: for a heating capacity (output) of 10 kW (e.g. 1st test condition) and an electrical power input of 2 kW, the COP value is 5 (10 kW / 2 kW = 5). This means that the electrical power used is transformed in 5 times more usable heat output.
Heat output: the useful heat output delivered by the heat pump under certain test conditions, in kW.
Example: B0/W35 means the brine-to-water heat pump is operated with 0°C brine source temperature and 35°C water supply temperature
Heat pump type | 1st test conditions | 2nd test conditions |
---|---|---|
Brine/water heat pump | B0/W35 | B0/W55 |
Water/water heat pump | W10/W35 | W10/W55 |
Air/water heat pump | A2/W35 | A-7/W35 |
Heat pump type:
SCOP – Seasonal Coefficient of Performance: According to standard EN 14825 the SCOP describes the heat pump’s average annual efficiency performance, and reflects themperatures and resulting COPs of different seasons. SCOP is therefore an expression for how efficient a specific heat pump will be for a given heating demand profile