Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the polylang domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /var/www/wp-includes/functions.php on line 6114
Beverage coolers – RefNat4Life
Back to product finder overview

Product finder plug-in refrigeration & heat pumps: Beverage coolers

Glossary of terms for Beverage coolers Glossary

The following glossary is based on information provided by topten.eu and taken from additional sources such as technical standards and legislative documents.

Refrigerated display cabinets, bottle coolers, and ice-cream freezers

Please note: A very good source for additional definitions for Refrigerated Display Cabinets is standard ISO 23953-1.

Ambient temperature: Suitable ambient temperature range in °C as recommended by the manufacturer.

Climate class: classification of the test room climate according to the dry bulb temperature and relative humidity (correction factor that accounts for the difference in ambient conditions for which the refrigerated display cabinets, bottle coolers and ice cream freezers are designed for)

Energy Efficiency Index (EEI): index number for the relative energy efficiency of a refrigeration appliance expressed in percentage (%), calculated according to the official EU regulation 2019/2018. The EEI is the basis for determining the energy efficiency class (energy label) from A to G.

Net volume: the usable part of the unit for storing or displaying foodstuffs, after deducting the volume of components and unusable spaces from the gross volume, in litres

Refrigerant: the product finder only lists models with natural refrigerants like R290 (propane), R600a (isobutane), R744 (carbon dioxide)

Temperature class: temperatures measured inside the cabinet during the energy consumption test. Classes are as follows:

Temperature classes for horizontal and vertical refrigerated display cabinets:

M0-1°C to +4°C
M1-1°C to +5°C
M2-1°C to +7°C
H1+1°C to +10°C
H2-1°C to +10°C
Max. temperatures of warmest m-pack:
θ ah (highest point)θ al (lowest point)
L1-15°C-18°C
L2-12°C-18°C
L3-12°C-18°C
Sother

Temperature classes for beverage coolers:

K10°C to +7°C, ∅≤ +3.5°C
K2-1°C to +6°C, ∅≤ +2.5°C
K3-3.5°C to +1°C, ∅≤ -1°C
K4+1°C to +9°C, ∅≤ +5°C
Sother

Temperature classes for ice-cream freezers:

C1-18°C
C2-7°C
Sother

Total display area (TDA): the total visible foodstuffs and other items area, including visible area through glazing, defined by the sum of horizontal and vertical projected surface areas of the net volume, in square meters (m2);

Filter results

Data source: www.topten.eu
Results: 66 Beverage coolers reset filters

Vestfrost

CC61

Typical energy use per 24 hr day: 0.3 kWh
Estimated electricity use over 8 years: 876 kWh
Technical data:
Temperature class: K4
Temperature range: +2...+8
Refrigerant: R600a
Climate class: 3 / CC1
Efficiency index: 12.2 %
Dimensions:
Height: 932 mm
Net volume: 59 l
Total display area: 0.34 m2
More info on manufacturer website

Vestfrost

FKG 274

Typical energy use per 24 hr day: 0.34 kWh
Estimated electricity use over 8 years: 992.8 kWh
Technical data:
Temperature class: K4
Temperature range: +4...+12
Refrigerant: R600a
Climate class: 3 / CC1
Efficiency index: 9.2 %
Dimensions:
Height: 850 mm
Width: 920 mm
Depth: 600 mm
Net volume: 210 l
Total display area: 0.36 m2
More info on manufacturer website

Vestfrost

M150

Typical energy use per 24 hr day: 1.32 kWh
Estimated electricity use over 8 years: 3857.32 kWh
Technical data:
Temperature class: K4
Temperature range: +2...+10
Refrigerant: R600a
Climate class: 3 / CC1
Efficiency index: 34.9 %
Dimensions:
Height: 155 mm
Width: 595 mm
Depth: 595 mm
Net volume: 222 l
Total display area: 0.63 m2
More info on manufacturer website

Vestfrost

M180

Series products:
M150
Typical energy use per 24 hr day: 1.35 kWh
Estimated electricity use over 8 years: 3930.32 kWh
Technical data:
Temperature class: K4
Temperature range: +2...+10
Refrigerant: R600a
Climate class: 3 / CC1
Efficiency index: 32 %
Dimensions:
Height: 185 mm
Width: 595 mm
Depth: 595 mm
Net volume: 283 l
Total display area: 0.79 m2
More info on manufacturer website

Vestfrost

M85

Series products:
M95
Typical energy use per 24 hr day: 0.49 kWh
Estimated electricity use over 8 years: 1424.96 kWh
Technical data:
Temperature class: K4
Temperature range: +2...+10
Refrigerant: R600a
Climate class: 3 / CC1
Efficiency index: 17.1 %
Dimensions:
Height: 830 mm
Width: 493 mm
Depth: 587 mm
Net volume: 110 l
More info on manufacturer website

Vestfrost

M95

Typical energy use per 24 hr day: 0.49 kWh
Estimated electricity use over 8 years: 1427.88 kWh
Technical data:
Temperature class: K4
Temperature range: +2...+10
Refrigerant: R600a
Climate class: 3 / CC1
Efficiency index: 16.1 %
Dimensions:
Height: 820 mm
Width: 595 mm
Depth: 575 mm
Net volume: 137 l
More info on manufacturer website