Back to product finder overview

Product finder plug-in refrigeration & heat pumps: Horizontal display cabinets

Glossary of terms for Horizontal display cabinets Glossary

The following glossary is based on information provided by topten.eu and taken from additional sources such as technical standards and legislative documents.

Refrigerated display cabinets, bottle coolers, and ice-cream freezers

Please note: A very good source for additional definitions for Refrigerated Display Cabinets is standard ISO 23953-1.

Ambient temperature: Suitable ambient temperature range in °C as recommended by the manufacturer.

Climate class: classification of the test room climate according to the dry bulb temperature and relative humidity (correction factor that accounts for the difference in ambient conditions for which the refrigerated display cabinets, bottle coolers and ice cream freezers are designed for)

Energy Efficiency Index (EEI): index number for the relative energy efficiency of a refrigeration appliance expressed in percentage (%), calculated according to the official EU regulation 2019/2018. The EEI is the basis for determining the energy efficiency class (energy label) from A to G.

Net volume: the usable part of the unit for storing or displaying foodstuffs, after deducting the volume of components and unusable spaces from the gross volume, in litres

Refrigerant: the product finder only lists models with natural refrigerants like R290 (propane), R600a (isobutane), R744 (carbon dioxide)

Temperature class: temperatures measured inside the cabinet during the energy consumption test. Classes are as follows:

Temperature classes for horizontal and vertical refrigerated display cabinets:

M0-1°C to +4°C
M1-1°C to +5°C
M2-1°C to +7°C
H1+1°C to +10°C
H2-1°C to +10°C
Max. temperatures of warmest m-pack:
θ ah (highest point)θ al (lowest point)
L1-15°C-18°C
L2-12°C-18°C
L3-12°C-18°C
Sother

Temperature classes for beverage coolers:

K10°C to +7°C, ∅≤ +3.5°C
K2-1°C to +6°C, ∅≤ +2.5°C
K3-3.5°C to +1°C, ∅≤ -1°C
K4+1°C to +9°C, ∅≤ +5°C
Sother

Temperature classes for ice-cream freezers:

C1-18°C
C2-7°C
Sother

Total display area (TDA): the total visible foodstuffs and other items area, including visible area through glazing, defined by the sum of horizontal and vertical projected surface areas of the net volume, in square meters (m2);

Filter results

Data source: www.topten.eu
Results: 198 Horizontal display cabinets reset filters

AHT

SYDNEY XL 250 (-) LDHF

Series products:
SYDNEY (-): EC 213 LDHF, EC 223 LDHF, XL 175 LDHF, XL 210 LDHF, XL 250 JKRT
Typical energy use per 24 hr day: 5.67 kWh
Estimated electricity use over 8 years: 16555.23 kWh
Technical data:
Temperature class: L1
Temperature range: -15 ... -18
Ambient temperature: 16 ... 25
Refrigerant: R290
Climate class: 3
Efficiency index: 22.6 %
Dimensions:
Height: 913 mm
Width: 2502 mm
Depth: 1043 mm
Net volume: 995 l
Total display area: 1.83 m2
More info on manufacturer website

AHT

SYDNEY XL 250 (U) JKRT

Typical energy use per 24 hr day: 8.75 kWh
Estimated electricity use over 8 years: 25535.69 kWh
Technical data:
Temperature class: L1
Temperature range: -15 ... -18
Ambient temperature: 16 ... 25
Refrigerant: R290
Climate class: 3
Efficiency index: 34.8 %
Dimensions:
Height: 913 mm
Width: 2502 mm
Depth: 1043 mm
Net volume: 963 l
Total display area: 1.83 m2
More info on manufacturer website

AHT

SYDNEY XL 250 (U) LDHF

Series products:
SYDNEY (U): EC 213 LDHF, EC 223 LDHF, XL 175 LDHF, XL 210 LDHF, XL 250 JKRT
Typical energy use per 24 hr day: 5.67 kWh
Estimated electricity use over 8 years: 16555.23 kWh
Technical data:
Temperature class: L1
Temperature range: -15 ... -18
Ambient temperature: 16 ... 25
Refrigerant: R290
Climate class: 3
Efficiency index: 22.6 %
Dimensions:
Height: 913 mm
Width: 2502 mm
Depth: 1043 mm
Net volume: 963 l
Total display area: 1.83 m2
More info on manufacturer website

ArcaBoa

1100 CHV/V

Typical energy use per 24 hr day: 4.9 kWh
Estimated electricity use over 8 years: 14308 kWh
Technical data:
Temperature class: L1
Temperature range: -16/-24
Ambient temperature: +16/+25
Refrigerant: R290
Climate class: 3
Efficiency index: 24.7 %
Dimensions:
Height: 780 mm
Width: 2500 mm
Depth: 960 mm
Net volume: 805 l
Total display area: 1.36 m2
More info on manufacturer website

ArcaBoa

750 CHV/V

Series products:
900 CHV/V, 1100 CHV/V
Typical energy use per 24 hr day: 3.9 kWh
Estimated electricity use over 8 years: 11388 kWh
Technical data:
Temperature class: L1
Temperature range: -16/-24
Ambient temperature: +16/+25
Refrigerant: R290
Climate class: 3
Efficiency index: 28 %
Dimensions:
Height: 780 mm
Width: 1550 mm
Depth: 960 mm
Net volume: 459 l
Total display area: 0.84 m2
More info on manufacturer website

ArcaBoa

900 CHV/V

Typical energy use per 24 hr day: 4.5 kWh
Estimated electricity use over 8 years: 13140 kWh
Technical data:
Temperature class: L1
Temperature range: -16/-24
Ambient temperature: +16/+25
Refrigerant: R290
Climate class: 3
Efficiency index: 25.7 %
Dimensions:
Height: 780 mm
Width: 2050 mm
Depth: 960 mm
Net volume: 652 l
Total display area: 1.16 m2
More info on manufacturer website

ArcaBoa

DUPLA 2.2 DE

Series products:
Dupla 2.2 DR
Typical energy use per 24 hr day: 9.2 kWh
Estimated electricity use over 8 years: 26864 kWh
Technical data:
Temperature class: L1
Temperature range: -16/-25
Ambient temperature: +16/+25
Refrigerant: R290
Climate class: 3
Efficiency index: 26.7 %
Dimensions:
Height: 990 mm
Width: 2150 mm
Depth: 1465 mm
Net volume: 1255 l
Total display area: 2.65 m2
More info on manufacturer website

ArcaBoa

DUPLA TOPO DE

Series products:
Dupla Topo DR
Typical energy use per 24 hr day: 4.1 kWh
Estimated electricity use over 8 years: 11972 kWh
Technical data:
Temperature class: L1
Temperature range: -16/-25
Ambient temperature: +16/+25
Refrigerant: R290
Climate class: 3
Efficiency index: 34.9 %
Dimensions:
Height: 902 mm
Width: 1470 mm
Depth: 811 mm
Net volume: 334 l
Total display area: 0.65 m2
More info on manufacturer website

ArcaBoa

Dupla 2.2 DR

Typical energy use per 24 hr day: 9.5 kWh
Estimated electricity use over 8 years: 27740 kWh
Technical data:
Temperature class: L1
Temperature range: -18...-23
Ambient temperature: +16...+25
Refrigerant: R290
Climate class: 3
Efficiency index: 27.6 %
Dimensions:
Height: 930 mm
Width: 2150 mm
Depth: 1465 mm
Net volume: 1255 l
Total display area: 2.65 m2
More info on manufacturer website

ArcaBoa

Dupla Topo DR

Typical energy use per 24 hr day: 3.93 kWh
Estimated electricity use over 8 years: 11475.6 kWh
Technical data:
Temperature class: L1
Temperature range: -18...-23
Ambient temperature: +16...+25
Refrigerant: R290
Climate class: 3
Efficiency index: 33.4 %
Dimensions:
Height: 902 mm
Width: 1470 mm
Depth: 811 mm
Net volume: 334 l
Total display area: 0.65 m2
More info on manufacturer website